Answers are grounded in this paper and cite their sources.
In this study, calorimeters were constructed with a thermocouple wire and an embedded optical fiber sensor, and the ATPV (Arc Thermal Performance Value) of a single layer arc rated fabric was determined. The results revealed differences between measurements obtained with the two sensor types. Notably, the absence of electromagnetic interferences of arc current on signals and the enhanced time response using the optical sensor led to an approximately 27% lower arc rating, in terms of ATPV, calculated for measurements performed with the optical sensor compared to those made with the thermocouple. These findings underscore the importance of investigating the current methodology used for determine arc ratings, to ensure accurate measurement of incident and transmitted energy.
No takes yet. Share an insight, caveat, or question.
Soares et al. (2024) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: