Direct exposure to high frequency radio frequency (HF RF) by the electrostatic chuck (ESC) leads to permanent damage to the ESC surface, which results in a process shift or clamping reliability problem. It is necessary to protect ESC during chamber cleaning and conditioning. This is done by covering the chuck with clampable protective ESC cover (CPEC). In this study, CPESs were prepared to study the impact of backside surface roughness towards universal pressure controller (UPC) fault, where the fault is a result of improper clamping that arise by leakage of backside cooling helium gas to the process chamber. Backside average roughness (Ra) for CPEC was measured at the outer edge. Ra values were collected, and it was found that covers with high backside Ra values lead to backside helium leakage and thus resulted in UPC faults during precoat deposition process. Fault trend data was collected for 5 consecutive months. It was observed that once backside Ra values of covers were controlled to a value no exceeding UPC fault rate dropped by 90% on the monitored tools. In general, low Ra is critical to prevent the UPC faults during precoat deposition process, with a corresponding reduction in tool downtime.