Recent developments in high-performance electrode materials have been pivotal for real-time monitoring biosensors, necessitating compatibility with biomaterials and robust electrochemi-cal properties. This study explores the development of electrode materials using single-walled carbon nanotubes (SWCNTs) and multi-walled carbon nanotubes (MWCNTs), with a primary fo-cus on assessing their dispersion and electrochemical properties. Various solvents, including N N-Dimethylformamide (DMF), deionized water, ethanol, and acetone, were used for dispersion analysis by employing ultrasonic waves. The results showed that SWCNTs exhibited well-dispersed characteristics without precipitation when introduced to a DMF solution. It found that resistance values decreased as the concentration of SWCNTs increased over the range of 0.025 to 0.4 g/L, with a considerable electrical conductivity reached at concentrations ranging from 0.2 g/L to 0.4 g/L in DMF. The biosensor platform was evaluated with 1-pyrenebutanoic acid succin-imidyl este (PBSE) as the linker and glucose oxidase (Gox) and chitosan as the binding substrate. The binding of Gox with glucose resulted in a significant decrease in resistance value of the biosensor with rising their concentrations ranged from 0.001 to 0.1 M. Though this research provides founda-tional insights for the advancement of SWCNT-based high-performance electrode materials, it will pave the way for the next generation of efficient and reliable biosensors.
No takes yet. Share an insight, caveat, or question.
Kim et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: