Answers are grounded in this paper and cite their sources.
This paper presents a self-adaptive correlated multiple sampling (SACMS) technique for low-noise CMOS image sensors. Compared to the traditional correlated multiple sampling (TCMS), SACMS technique adds a pre-determination stage to determine the brightness of the pixel, reducing the 4 large-range ramps to 3 small-range ramps and 1 large-range ramp when quantizing the signal. For dark pixels, the signal is quantized using small-range ramps with short sampling interval to reduce low-frequency noise. For bright pixels, the CMS operation is turned off and the signal is quantized only once in the large-range ramp to improve the frame rate. Simulation results demonstrate that, for dark pixels, SACMS achieves a minimum readout noise of 84.22μV rms at eight times analog gain, compared to 108.76μV rms with TCMS, representing an approximately 21.7 % improvement in noise suppression . Additionally, the sampling rate of the SSADC employing SACMS technique is 36.36 kHz, while the sampling rate of the SSADC using TCMS technique is 21 kHz.
No takes yet. Share an insight, caveat, or question.
Zheng et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: