In order to further improve heat transfer performance and high compactness of plate-fin heat exchangers (PFHEs) in cryogenic helium systems, a new type of perforated-serrated fins is proposed by combining traditional serrated and perforated fins. In this paper, the flow and heat transfer characteristics of helium in perforated-serrated fins and serrated fins channels at low-temperature are investigated using numerical simulations. The numerical model invokes the properties of low-temperature helium by NIST-Real-Gas-Model. Meanwhile, Colburn factor j , friction factor f and JF factor are qualitatively evaluated for pressure drop, heat transfer performance and thermo-hydraulic performance, respectively. The results show that new perforated-serrated fins have better heat transfer performance. The j factor of the new fins increases by 32.58% to 15.63% compared with serrated fins. The flow performance of perforated-serrated fins is slightly worse than that of serrated fins, but the overall thermo-hydraulic performance is better, especially at low Reynolds number. Compared with serrated fins, the JF factor of perforated-serrated fins is significantly higher and increase by 25.95% to 10.86%. The optimizing method of fins structure can be used in the actual design of PFHEs in cryogenic helium systems.
No takes yet. Share an insight, caveat, or question.
Zou et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: