Noncontact measurement of current and voltage poses various challenges in different applications. In this article, a novel differential reconstruction method for noncontact and simultaneous measurements of current and voltage as well as power on a printed trace is proposed. The principles and calculation procedures of the method are explained in detail. Compared with the previous segregated reconstruction method using a compact probe with both a current detector and voltage detector, the differential method employing a differential probe with a single-loop structure is well characterized through a series of comparison tests, including measured and calculated response tests, time delay difference tests, and reconstruction performance tests. Especially for time delay difference levels and the reconstruction performance, the proposed method is validated to exhibit a more than tenfold decrease in the time delay difference levels and a less than 5% average curve error. Finally, a real application involving the switching behaviors at the output of a customized pulsewidth modulation (PWM) generator module is presented with an average curve error of 3.8%. These results further support the feasibility and effectiveness of the proposed method.
No takes yet. Share an insight, caveat, or question.
Luo et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: