Answers are grounded in this paper and cite their sources.
Model-based evaluation and optimization of technical extraction columns are necessary when the product specifications of a technical system (TS) are not reached. However, state-of-the-art models are parameterized and validated using standard test systems (STSs) of highest purity. In contrast to that, TSs are characterized by an incomplete list of components, impurities, and batch-depending physicochemical properties. This divergence between STSs and TSs results in a lack of trust regarding developed model-based approaches for extraction columns. In this paper, an experimental approach for parameterization of a one-dimensional rate-based model is presented. The model is parameterized for a STS leading to a weighted absolute percentage error, WAPE¯wAcetone,out, of 8.53%. The parameter set is then used for a TS leading to a WAPE¯wTC,out of 17.43%. The distribution coefficient is the most sensitive model parameter as a change in the distribution coefficient of 3% yields a relative change of WAPE¯wTC,out by 19.39%. Varying the fluid dynamics parameters Sauter diameter and hold-up by 20%, the relative change in WAPE¯wTC,out is 44.03% and only 5.48%, respectively. A recommendation for minimal instrumentation for lab-scale extraction columns and technical large-scale columns is given.
No takes yet. Share an insight, caveat, or question.
Brockkötter et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: