Introduction The hypoglossal nerve stimulation (HNS) system from Inspire Medical Systems, Inc (Golden Valley, MN) monitors respiration with a pressure sensor to deliver stimulation during inspiration. The sensor is embedded in a lead that is typically implanted in the second intercostal space and anterior to the generator. Inspiratory phase overlap fraction (IPOF) is the fraction of the inspiration phase concurrent with the stimulation burst. An accelerometer embedded in the generator to replace the implanted sensor lead could simplify the HNS system and implant procedure. To test whether an accelerometer control system performs comparably to the pressure sensor control system, we compared the IPOF of the commercial HNS system to that derived from an externally mounted accelerometer. Methods Fifty-six patients previously implanted with an HNS system (8 Inspire II, 48 Inspire IV) underwent a polysomnogram (PSG) while also wearing two accelerometers on their chest (approximately 5 cm below each the left and right clavicle, a typical implant location). The commercial system stimulation timing was exported and time-aligned with the PSG waveform to calculate the commercial system’s IPOF. The accelerometer waveforms were exported and time-aligned with the PSG respiration sensor, then the sensing algorithm was applied to the accelerometer waveforms to determine stimulation timing and calculate the accelerometer system’s IPOF. IPOF is reported as mean ± standard deviation [95% confidence interval for the mean]. The entire cohort was used in commercial system analysis but was divided into separate groups for accelerometer algorithm tuning and validation. Results Commercial system IPOF was 78%±7%, 95%CI [76%-79%] (n=56, 298 sleep hours). Accelerometer system IPOF was 86%±6%, 95%CI [84%-88%] in the tuning group (n=26, 133 sleep hours) and 83%±8%, 95%CI [80%-85%] in the validation group (n=30, 165 sleep hours). Conclusion Results from this study demonstrate an externally worn accelerometer based IPOF is comparable to the pressure sensor based IPOF of the implanted HNS system. This suggests an accelerometer control system embedded in the generator could replace the implanted pressure sensor to provide at least equivalent stimulation delivery. Support (if any) This study was funded by Inspire Medical Systems. Inspire employees contributed to the study execution and data analysis.
No takes yet. Share an insight, caveat, or question.
Roy et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: