This paper is concerned with a hydraulic cylinder directly controlled by a variable speed fixed displacement pump. The considered configuration is referred to as a one-motor-one-pump (1M1P) motor-controlled hydraulic cylinder (MCC). A 1M1P MCC with a hydraulically driven passive load-holding function enabled by controlled system pressures is proposed. The proposed load-holding functionality works if there is a standstill command, a loss of power supply, or a hose rupture. Additionally, this paper conducts a comprehensive analysis of the proposed system's operation and load-holding function across four quadrants. Simulation results demonstrate the four-quadrant operation and good load-holding performance under the aforementioned scenarios. In conclusion, the proposed 1M1P MCC can be successfully used on practical applications characterized by overrunning loads and four quadrant operation.
No takes yet. Share an insight, caveat, or question.
Zhao et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: