Power cycling tests (PCTs) assess the reliability of power devices by closely simulating their operating conditions. A PCT was performed on commercially available 1.2 kV 4H-SiC power metal–oxide–semiconductor field-effect transistors to observe its impact on the 4H-SiC/SiO2 interface. High-resolution transmission electron microscopy and electron energy loss spectroscopy measurements showed variations in the length of the 4H-SiC/SiO2 transition layer, depending on whether the device was power cycled. Moreover, the total resistance at Vg≫ Vt in Rtot − (Vg-Vt)−1 graph increased to 16.5%, while it changed more radically to 47.3% at Vg≈ Vt. The threshold voltage shifted negatively. These variations cannot be expected solely through the wearout of the package.
No takes yet. Share an insight, caveat, or question.
Yoo et al. (2024) studied this question.