The emission of carbon dioxide (CO 2 ) by thermal power plants is the main factor leading to the greenhouse effect. The measurement of CO 2 is of great significance to carbon emission data statistics. In this paper, a measurement system based on tunable diode laser absorption spectroscopy (TDLAS) was built to measure the spectrum of CO 2 near 1579 nm. To simplify the experimental system, a direct absorption signal fitting method is proposed to replace etalons for time‐frequency conversion. The method was applied to the measurement of four different concentrations of CO 2 in the range of 7%–16%, and the measurement results were compared with the multipeak method, another etalon‐free method. The results show that the mean relative error of the measurement results is 4.23%, which is 1.76% lower than the measurement results of the multipeak method. The experimental research provides a feasible idea to simplify the CO 2 measurement system based on TDLAS.