We report measurements of radon progeny in liquid argon within the MicroBooNE time projection chamber (LArTPC). The presence of specific radon daughters in MicroBooNE’s 85 metric tons of active liquid argon bulk is probed with newly developed charge-based low-energy reconstruction tools and analysis techniques to detect correlated <a:math xmlns:a="http://www.w3.org/1998/Math/MathML" display="inline"><a:mrow><a:mmultiscripts><a:mrow><a:mi>Bi</a:mi></a:mrow><a:mprescripts/><a:none/><a:mrow><a:mn>214</a:mn></a:mrow></a:mmultiscripts><a:mtext>−</a:mtext><a:mrow><a:mmultiscripts><a:mrow><a:mi>Po</a:mi></a:mrow><a:mprescripts/><a:none/><a:mrow><a:mn>214</a:mn></a:mrow></a:mmultiscripts></a:mrow></a:mrow></a:math> radioactive decays. Special datasets taken during periods of active radon doping enable new demonstrations of the calorimetric capabilities of single-phase neutrino LArTPCs for <c:math xmlns:c="http://www.w3.org/1998/Math/MathML" display="inline"><c:mi>β</c:mi></c:math> and <e:math xmlns:e="http://www.w3.org/1998/Math/MathML" display="inline"><e:mi>α</e:mi></e:math> particles with electron-equivalent energies ranging from 0.1 to 3.0 MeV. By applying <g:math xmlns:g="http://www.w3.org/1998/Math/MathML" display="inline"><g:mrow><g:mmultiscripts><g:mrow><g:mi>Bi</g:mi></g:mrow><g:mprescripts/><g:none/><g:mrow><g:mn>214</g:mn></g:mrow></g:mmultiscripts><g:mtext>−</g:mtext><g:mrow><g:mmultiscripts><g:mrow><g:mi>Po</g:mi></g:mrow><g:mprescripts/><g:none/><g:mrow><g:mn>214</g:mn></g:mrow></g:mmultiscripts></g:mrow></g:mrow></g:math> detection algorithms to data recorded over a 46-day period, no statistically significant presence of radioactive <i:math xmlns:i="http://www.w3.org/1998/Math/MathML" display="inline"><i:mrow><i:mmultiscripts><i:mrow><i:mi>Bi</i:mi></i:mrow><i:mprescripts/><i:none/><i:mrow><i:mn>214</i:mn></i:mrow></i:mmultiscripts></i:mrow></i:math> is detected, and a limit on the activity is placed at <k:math xmlns:k="http://www.w3.org/1998/Math/MathML" display="inline"><k:mo form="prefix"><</k:mo><k:mn>0.35</k:mn><k:mtext> </k:mtext><k:mtext> </k:mtext><k:mi>mBq</k:mi><k:mo>/</k:mo><k:mi>kg</k:mi></k:math> at the 95% confidence level. This bulk <n:math xmlns:n="http://www.w3.org/1998/Math/MathML" display="inline"><n:mrow><n:mmultiscripts><n:mrow><n:mi>Bi</n:mi></n:mrow><n:mprescripts/><n:none/><n:mrow><n:mn>214</n:mn></n:mrow></n:mmultiscripts></n:mrow></n:math> radiopurity limit—the first ever reported for a liquid argon detector incorporating liquid-phase purification—is then further discussed in relation to the targeted upper limit of <p:math xmlns:p="http://www.w3.org/1998/Math/MathML" display="inline"><p:mrow><p:mn>1</p:mn><p:mtext> </p:mtext><p:mtext> </p:mtext><p:mi>mBq</p:mi><p:mo>/</p:mo><p:mi>kg</p:mi></p:mrow></p:math> on bulk <r:math xmlns:r="http://www.w3.org/1998/Math/MathML" display="inline"><r:mrow><r:mmultiscripts><r:mrow><r:mi>Rn</r:mi></r:mrow><r:mprescripts/><r:none/><r:mrow><r:mn>222</r:mn></r:mrow></r:mmultiscripts></r:mrow></r:math> activity for the DUNE neutrino detector. Published by the American Physical Society 2024
No takes yet. Share an insight, caveat, or question.
Abratenko et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: