Experimental study demonstrates reduced copper loss in a doubly salient electromagnetic generator under excitation loss, indicating viable fault-tolerant power generation.
The excitation loss of doubly salient electromagnetic generator (DSEG) can be caused by the fault in the excitation winding due to aging, overheating, external force impacts, as well as the fault in the excitation power converter due to reasons such as over-current and reverse voltage shocks, which makes the system exhibit abnormal operation. Consequently, a fault-tolerant power generation (FTPG) strategy is proposed for the DSEG system under excitation loss, which can enhance the DSEG's fault-tolerant capability and mitigate the copper loss. First, this paper analyzes the fundamental principles of normal power generation in DSEG, establishes its mathematical model under excitation loss, and investigates the fault-tolerant control strategy. Subsequently, this paper analyzes the mechanism behind the high copper loss issue in implementing the positive and negative excitation angle control (PNEAC) strategy during the fault-tolerant operation of the DSEG under excitation loss. Furthermore, a positive and negative current given control (PNCGC) strategy with an advanced angle is proposed for FTPG, to optimize copper loss of DSEG under excitation loss. According to the mentioned hypothesis, some experiments are performed on an 18/12 pole DSEG system to demonstrate the feasibility and effectiveness of the proposed strategy.
No takes yet. Share an insight, caveat, or question.
Shi et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: