Typical usage scenarios for energy storage and electric vehicles (EVs) require lithium-ion batteries (LIBs) to operate under extreme conditions, including varying temperatures, high charge/discharge rates, and various depths of charge and discharge, while also fulfilling vehicle-to-grid (V2G) interaction requirements. This study empirically investigates the impact of ambient temperature, charge/discharge rate, and charge/discharge cut-off voltage on the capacity degradation rate and internal resistance growth of 18,650 commercial LIBs. The charge/discharge rate was found to have the most significant influence on these parameters, particularly the charging rate. These insights contribute to a better understanding of the risks associated with low-temperature aging and can aid in the prevention or mitigation of safety incidents.