Answers are grounded in this paper and cite their sources.
The present work emphasizes the effect of graphene nanoplatelets (G) filler loading on mechanical and abrasive wear behavior of carbon fibre reinforced epoxy (C/E) composites. Graphene nanoplatelets were mixed with epoxy framework using a temperature-controlled magnetic stirrer and then ultrasonically treated. The parameters considered for the abrasive wear study are the applied load in N (5, 10 and 15), abrading distance in m (75, 150, and 225) and weight percentage of reinforcement (0, 1, and 1.5). The incorporation of 1 wt. % G into C/E composites increases hardness by 14 % and interlaminar laminar strength by 19 % when compared to C/E composites. According to the Taguchi design of tests, a filler loading of 1 wt. % G, an abrading distance of 225 m, and an applied load of 15 N are ideal. Analysis of variance (ANOVA) was done to establish the dominant parameter, and the filler loading with abrading distance was shown to be significant. With 36.4 %, the filler loading had the biggest influence on the composite specific wear rate. The combination of filler loading with 1 wt. %, load of 15 N, and abrading distance of 225 m yields the lowest specific wear rate. The involved wear mechanisms during the abrasive wear process have also been explained with scanning electron micrographs.
No takes yet. Share an insight, caveat, or question.
Shivamurthy et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: