Answers are grounded in this paper and cite their sources.
This research demonstrates a new A-scanner that detects grout voids in post-tensioned bridges, suggesting improved tendon safety.
Grout voids in external tendons of post-tensioned bridges are a critical issue, as they may result in the corrosion of the steel strands and significantly reduce tendon strength. Therefore, preventing tendon failure necessitates thorough inspection for these voids during both construction and operation. Terahertz electromagnetic wave testing is an effective method for detecting voids between the protective duct and the grout in external tendons, as terahertz waves can penetrate through the protective duct. This study introduces a D-band electronic frequency-modulated continuous-wave terahertz A-scanner for enhanced real-time inspection. The proposed method offers key advantages such as miniaturization, cost-effectiveness, and robustness, while providing effective detection of voids beneath the duct in external tendons. It is indicated that voids with a thickness of approximately 2.5 mm or greater can be detected using the D-band THz A-scanner.
No takes yet. Share an insight, caveat, or question.
Yee et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: