This method achieves frequency stability using a closed-loop feedback system, suggesting practical applications for precision optics.
We present a compact laser frequency stabilization method by locking a 556 nm laser to a high-precision wavelength meter. Unlike traditional schemes that rely on optical cavities or atomic references, we stabilize the laser frequency via a closed-loop feedback system referenced to a wavelength meter. This configuration effectively suppresses long-term frequency drifts, achieving frequency stability to the wavelength meter's shot-noise-limited resolution. The system enables sub-hundred-kilohertz stability without complex optical components, making it suitable for compact or field-deployable applications. Our results demonstrate that, with proper feedback design, wavelength meter-based locking can offer a practical and scalable solution for precision optical experiments requiring long-term frequency stability.
No takes yet. Share an insight, caveat, or question.
Gan et al. (2025) studied this question.