PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
October 17, 2025Scientific Reports3 citationsOpen Access

Designing and field calibration of low-cost microcontroller-based soil moisture sensor for subsurface drip-irrigation system

View Full Paper
ARAmina RahejaRSRakesh ShardaSGSunil Garg

Key Points

  • The developed low-cost capacitive soil moisture sensor demonstrated consistent performance in field tests, ensuring reliability for irrigation management.
  • Regression analysis revealed strong predictive capability for soil moisture levels, with Mean Absolute Error of 1.56% and strong correlation coefficients exceeding 0.98.
  • Field calibration of the new sensor system achieved performance comparable to the commercial SM150T sensor, highlighting its utility for agricultural applications.
  • The study emphasizes the potential of this low-cost sensor for effective irrigation management with minimal impact on efficiency.

Abstract

A cost-effective capacitive sensor system, SEN0193, was ruggedised, calibrated, and evaluated in both laboratory and field settings to assess sensor-to-sensor variability resulting from sensor placement in the soil. Experimental data underwent regression analysis to develop a model for predicting soil moisture levels using the output voltage of the capacitive sensor, as recorded at the Analog-to-Digital Converter (ADC) of the microcontroller. The accuracy of the developed low-cost sensor system was demonstrated through the evaluation of Mean Absolute Error, Root Mean Square Error, and Relative Absolute Error, yielding values of 1.56%, 0.36, and 0.65, respectively. A comparison was conducted between the field-calibrated soil sensing system and a commercial SM150T sensor to measure Volumetric Water Content (VMC) in a sugarcane field. The Spearman rank correlation coefficient for Volumetric Water Content (VMC) prediction using the new low-cost sensor and the commercial SM150T sensor exceeded 0.98, indicating a strong and positive correlation between the two sensors' readings. Throughout the entire field testing period, the low-cost capacitive soil moisture sensor system exhibited consistent and reliable performance, with no practical issues reported. After soil-specific calibration, the low-cost capacitive sensors in the group demonstrated performance on par with commercially available sensors. This finding suggests that these sensors can be efficiently employed for irrigation management, with minimal impact on irrigation efficiency.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Raheja et al. (2025) studied this question.

synapsesocial.com/papers/68f25c913dc7eb0776cbc0a7https://doi.org/10.1038/s41598-024-81288-z
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Analysis of the Variability in Soil Moisture Measurements by Capacitance Sensors in a Drip-Irrigated Orchard2020 · 42 citations
  2. 2A method of measuring soil moisture by time-domain reflectometry1986 · 485 citations
  3. 3Performance Evaluation of Real Time Automatic Irrigation System on the Yield of Cabbage (Brassica oleracea L.)2019 · 5 citations
  4. 4Credibility2011 · 35 citations
  5. 5Standardizing Characterization of Electromagnetic Water Content Sensors: Part 1. Methodology2005 · 181 citations