Calibration strategies improve automated drip irrigation accuracy in upland farms, suggesting optimal moisture management practices.
Upland, rainfed farms in the Philippines require precise irrigation to manage scarce water resources efficiently. To address this, we developed an Arduino-based automated drip irrigation system using six low-cost analog capacitive soil-moisture sensors and a normally closed solenoid valve, triggered by a simple threshold control mechanism. The sensors were calibrated in the laboratory using loamy sand and evaluated through two strategies: a pooled general model and sensor-specific models. Exponential regression yielded the best monotonic fit (R² = 0.94–0.97). Compared to the general model (RMSE = 2.42–3.37%), sensor-specific calibrations improved both precision (CV < 10%) and accuracy (RMSE = 1.81–2.67%). Although mean differences and R² values were not statistically significant (paired T-test, α = 0.01), the general equation remains practical for field deployment. However, sensor-specific equations are preferable when higher accuracy is required. At higher moisture levels (36–46% VWC), the sensors tended to overestimate, suggesting increased error near the wet end of the scale. Overall, the low-cost system functioned reliably, demonstrating a viable, moisture-responsive irrigation control solution for small- to medium-sized upland plots.
No takes yet. Share an insight, caveat, or question.
Cabia et al. (2025) studied this question.