This analysis demonstrates effective protection of construction pits in complex geotechnical conditions, indicating improved safety and efficiency.
Protection of a construction pit represents a challenging engineering task, especially when limiting factors such as high groundwater levels, the presence of adjacent structures, weak soil strength characteristics, and large excavation depths are present. This study addresses a technical solution that provides a dual function: protection of the construction pit during the construction phase and an underground structure (garage) with its own functional use during operation. The proposed solution involves the use of reinforced concrete panels – diaphragm walls – constructed using the “top-to-down” method. This method allows the simultaneous construction of the above-ground and underground parts of the building with minimal impact on the surroundings and increased safety during work.
No takes yet. Share an insight, caveat, or question.
Vojnoska et al. (2025) studied this question.