Answers are grounded in this paper and cite their sources.
Experimental tests and numerical simulations indicated barriers affect liquid flow rate and vortex flow stability.
The paper presents the results of tests of flow regulators with a triangular prismatic cross-section chamber. The aim of the paper was to experimentally and numerically (CFD) assess the water flow for different design variants of the regulators. Three variants of flow regulators with a triangular prismatic cross-section chamber were analysed: without a barrier (FRWB), with a short barrier (FRSB), and with a long barrier (FRLB). Simultaneously, numerical simulations were carried out using the SST k-ω turbulence model (CFD). The obtained flow characteristics Q = f(H) showed the clear effect of the presence and length of the barrier on the efficiency of flow restriction. The regulators with a long barrier (FRLB) provided the highest flow damping and the highest stability of the system’s operation, which was confirmed by the experimental tests and CFD analyses. The regulators without a barrier (FRWB) were characterized by the highest liquid flow rate and the lowest damping efficiency. The use of a long barrier allowed for an increased control efficiency and improved predictability of the device’s operation. The triangular cross-section of the chamber favours the formation of a stable vortex flow and increases the efficiency of the regulator’s operation.
No takes yet. Share an insight, caveat, or question.
Ochowiak et al. (2025) studied this question.