Answers are grounded in this paper and cite their sources.
Conical vortex regulators provide passive control of stormwater discharge, but their performance depends on inlet and outlet geometry. Sixteen 3D-printed laboratory-scale regulators were tested with water at hydrostatic heads of 0.1–1.7 m, and seven selected geometries were simulated at H = 1.0 m using steady-state, single-phase CFD in ANSYS Fluent with the SST k–ω turbulence model and nonuniform near-wall resolution. For the reference regulator, mesh sensitivity of integral discharge was assessed up to 256,791 elements; mesh G3 (158,038 elements) was used for detailed flow-field analysis. The inlet-area-referenced discharge coefficients ranged from 0.24 to 0.70. The effects of outlet enlargement on μ were geometry-dependent, with diminishing sensitivity observed for some inlet-diameter series but not established as a universal plateau. For two representative geometries, Q followed √H with R2 = 0.9966 and 0.9960. CFD reproduced the principal discharge trends with a mean absolute percentage error of 6.94%; six of seven deviations were below 8%, while the largest was −15.18%. A central air core was observed experimentally, whereas the single-phase CFD resolved only a low-pressure liquid core. The Wójtowicz–Kotowski correlation underpredicted μ by approximately a factor of two, but the present inlet angle and part of the Froude-type range lie outside its calibration domain.
No takes yet. Share an insight, caveat, or question.
Ochowiak et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: