Observational analysis reveals changes in flame structure with varying pilot equivalence ratios, indicating critical pilot fuel interactions.
The pilot flame serves as the primary anchor for global flame stabilization in a centrally staged combustor. In engineering practice, it typically operates in the diffusion mode. The fuel non-uniformity and diffusion kinetics of the pilot flame may have a significant impact on the flow and flames within the combustor. The flame structure and flame–flow interaction in a centrally staged burner featuring a diffusion pilot flame are investigated in the present paper, using high-frequency CH2O planar laser-induced fluorescence (CH2O-PLIF), CH* chemiluminescence, and particle image velocimetry (PIV) measurements. The stratified flame (S-flame) and the lifted flame (L-flame) are identified under two-stage conditions. The S-flame and L-flame correspond to the separated flow and the merged flow of the two stages, respectively. Significant radial oscillation of the pilot stage airflow is also found. Extensive tests demonstrate that the pilot equivalence ratio (Φp) plays an important role in flame mode switching. Silicone droplets with extremely fine sizes are introduced into the pilot fuel to trace its transportation. When the oscillating pilot stage airflow rushes towards the lip in an instant, it can entrain the pilot fuel to reach the inner side of the main stage outlet. With a low pilot fuel supply and relatively low injection velocity, the pilot fuel and the hot radicals are more likely to be entrained and accumulate in larger amounts at the inner side of the main stage outlet. Consequently, the main stage premixed mixture can be ignited at the main stage outlet, forming the S-flame. The flame mode switches from S- to L-flame when the equivalence ratio increases to the point where the corresponding velocity ratio of pilot fuel to air (Vfp/Vap) approaches 1.0, with a reduced entrainment of the pilot fuel and radicals. Simultaneous CH2O-PLIF and flow field results show that when the main stage is ignited downstream, hot products cannot recirculate to the pilot stage outlet, causing the extinction of the pilot flame root. This paper reveals that the fuel diffusion characteristics of the pilot stage can dramatically change the flame structure. To achieve the ideal designed flame shape, the interaction between the pilot fuel and pilot air requires very careful treatment in practical centrally staged combustors.
No takes yet. Share an insight, caveat, or question.
Mo et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: