Development and validation of a mobile system to assess condensation and thermal conductivity, indicating potential for improved energy efficiency.
Hygrothermal assessment plays a critical role in the design and maintenance of healthy, energy-efficient buildings. Despite established knowledge of condensation mechanisms and mitigation strategies, condensation and moisture remains a persistent issue even in newly constructed structures. This ongoing challenge highlights the need for empirical validation of data critical to condensation occurrence. This study presents the development and evaluation of a mobile, on-site measurement system designed to collect data on surface condensation and thermal conductivity of building walls. The system is developed using a data acquiring and processing platform myRIO built around LabVIEW, enabling real-time detection of critical condensation conditions and deviations in thermal conductivity from measured values. Measurement results were validated with the Heat Flow Method (HFM) and theoretical calculations at the same site.
No takes yet. Share an insight, caveat, or question.
Štambuk et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: