Key result
Corrected PISA reduces tricuspid regurgitation underestimation, doubling measured EROA to 1.31 cm² versus standard PISA.
Why the study?
Does correcting the PISA method for flow, leaflet angle, and orifice ellipticity improve the quantitative assessment of tricuspid regurgitation severity compared to standard PISA?
Observational (n=100)
Does correcting the PISA method for flow, leaflet angle, and orifice ellipticity improve the quantitative assessment of tricuspid regurgitation severity compared to standard PISA?
Correcting the PISA method for geometric assumptions reduces the underestimation of tricuspid regurgitation severity and provides independent prognostic value for morbidity and mortality.
Aims The primary quantitative measure of tricuspid regurgitation (TR) severity uses the proximal isovelocity surface area (PISA) method to calculate effective regurgitant orifice area (EROA) and regurgitant volume (RegVol). However, EROAPISA has been demonstrated to underestimate TR severity due to reliance of several geometric assumptions. The aim of this study was to evaluate if correcting for these parameters would improve this underestimation. Methods and Results Patients with at least mild TR identified on transthoracic echocardiography were included in the study. EROAPISA and EROACORRECTED were compared with quantitative Doppler (EROADOPPLER) and 3-dimensional vena contracta area (3D-VCA). EROAPISA was corrected for flow, leaflet angle, and regurgitant orifice ellipticity (EROACORRECTED). Of 100 patients included in the study, EROAPISA (0.62 ± 0.47 cm2) was significantly lower than EROADOPPLER (1.40 ± 1.11 cm2) and 3D-VCA (1.66 ± 1.18 cm2). EROACORRECTED reduced the underestimation (1.31 ± 1.19 cm2, p = 0.73). Both EROAPISA and EROACORRECTED correlated well to EROADOPPLER (r = 0.81, r = 0.8, p < 0.001 for both) and 3D-VCA (r = 0.76, r = 0.70, p < 0.001 for both), although EROACORRECTED had higher agreement to both methods. EROACORRECTED ≥ 0.75 independently predicted morbidity and mortality on univariate (HR 1.84, CI 1.10-3.15, p = 0.02) and multivariate analysis (HR 2.00, CI 1.10-3.90, p = 0.04). EROADOPPLER and 3D-VCA ≥ 0.75 were also associated with worse outcomes on multivariate analysis. Conclusion Correcting PISA for flow, leaflet angle, and regurgitant orifice shape reduced its underestimation, and demonstrated high correlation and improved agreement with other quantitative methods.
No takes yet. Share an insight, caveat, or question.
Tat et al. (2025) conducted an observational in Tricuspid regurgitation (n=100). Corrected proximal isovelocity surface area (EROACORRECTED) vs. Standard PISA (EROAPISA) was evaluated on Effective regurgitant orifice area (EROA) (p=0.73). Correcting the proximal isovelocity surface area (PISA) method for flow, leaflet angle, and orifice shape reduced underestimation of tricuspid regurgitation severity (1.31 vs 0.62 cm2).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: