Answers are grounded in this paper and cite their sources.
Cross-testing of gonioreflectometers highlights the effect of r-table measurement uncertainties on lighting quality.
Knowing the reflective properties of road surfaces is an important lever for optimizing the performance of lighting installations. Nevertheless, measuring these properties is still a confidential exercise, and the uncertainties associated with r-table measurements are rarely evaluated. Based on a cross-test campaign between 3 laboratory gonioreflectometers, we investigated the effect of the dispersion of r-table measurements on the quality criteria of a lighting installation. We were able to show that these dispersions were still acceptable, and that characterizing the optical properties of a pavement is an advantage over the traditional use of CIE standard r-tables. By carrying out these measurements in different observation geometries, we also showed that reconsidering the standard 1° geometry would offer the possibility of reducing measurement uncertainties. This contributes to current research aimed at better integrating different types of night-time mobility into urban lighting practices.
No takes yet. Share an insight, caveat, or question.
Liandrat et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: