The Fat Attenuation Index (FAI) measured by DLIR-H was significantly higher than that measured by ASiR-V50% and FBP in coronary CTA (p < 0.05).
Does the choice of CCTA reconstruction algorithm affect the measurement of coronary Fat Attenuation Index (FAI) in patients undergoing CCTA?
Coronary Fat Attenuation Index (FAI) values vary significantly depending on the CCTA reconstruction algorithm used, highlighting the need for standardized protocols to ensure reproducible results in multicenter and longitudinal studies.
Absolute Event Rate: 0% vs 0%
The Fat Attenuation Index (FAI) surrounding the coronary arteries, a sensitive biomarker for coronary inflammation, can be measured through standard Coronary Computed Tomography Angiography (CCTA). The aim of this study is to evaluate the differences in FAI as displayed on CCTA using three different reconstruction algorithms: high-level Deep Learning Image Reconstruction (DLIR-H), adaptive statistical iterative reconstruction-Veo at a level of 50% (ASiR-V50%), and Filtered Back Projection (FBP). Based on the presence or absence of plaque, the population was divided into the following groups: normal, no plaque, non-calcified plaque, mixed plaque, and calcified plaque. Each group was then further analysed according to the reconstruction algorithm, with three subgroups for each: DLIR-H, ASiR-V50%, and FBP. Attenuation values for pericardial adipose tissue, image noise, and the Fat Attenuation Index (FAI) of the three proximal coronary arteries were measured and evaluated for each of the three reconstruction algorithms. The attenuation values of pericardial adipose tissue measured by the three algorithms were not statistically different. However, the FAI measured by DLIR-H was the highest, followed by ASiR-V50%, with FBP yielding the lowest value; all differences were statistically significant. Meanwhile, DLIR-H demonstrated the strongest ability to reduce image noise, whereas FBP showed the weakest ability to do so. FAI varies significantly depending on the algorithm used. Therefore, standardised reconstruction protocols are essential in multicentre and longitudinal studies to ensure accurate, reproducible, and comparable FAI results.
Zhu et al. (Mon,) reported a other. The Fat Attenuation Index (FAI) measured by DLIR-H was significantly higher than that measured by ASiR-V50% and FBP in coronary CTA (p < 0.05).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: