Key result
Mock circulatory loops enhance pre-clinical evaluation of aortic therapies across 84 studies.
Why the study?
This review aimed to systematically map the current landscape of mock circulatory loops used for aortic simulation and identify major areas of application.
Mock circulatory loops represent a versatile pre-clinical platform for studying aortic pathophysiology and testing endovascular therapies, though standardized reporting frameworks are needed.
Supports mock circulatory loops for pre-clinical aortic device validation; extends systematic mapping of their biomechanics and hemodynamics applications.
Background: Mock circulatory loops (MCLs) are benchtop experimental platforms that reproduce key features of the human cardiovascular system, providing a safe, controlled, and reproducible environment for haemodynamic investigation. This scoping review aims to systematically map the current landscape of MCLs used for aortic simulation and identify major areas of application. Methods: A systematic search of PubMed, Scopus, and Web of Science identified original studies employing MCLs for aortic simulation. Eligible studies were categorized into predefined themes: (I) (bio)mechanical aortic characterization, (II) hemodynamics, (III) device testing, (IV) diagnostics, and (V) training. Data on MCL configurations, aortic models, and study objectives were synthesized narratively. Results: Eighty-four studies met the inclusion criteria. Twenty-five investigated aortic biomechanics, 23 hemodynamics, 22 device or product testing, 13 validated diagnostic imaging techniques, and one training application. Models included porcine (n = 22), human cadaveric (n = 7), canine (n = 1), ovine (n = 1), bovine (n = 1), and 3D-printed or molded aortic phantoms (n = 55). MCLs were employed to study parameters such as aortic stiffness, flow dynamics, dissection propagation, endoleaks, imaging accuracy, and device performance. Conclusions: This review provides a comprehensive overview of MCL applications in aortic research. MCLs represent a versatile pre-clinical platform for studying aortic pathophysiology and testing endovascular therapies under controlled conditions. Standardized reporting frameworks are now required to improve reproducibility and accelerate translation to patient-specific planning.
No takes yet. Share an insight, caveat, or question.
Osinga et al. (2025) studied this question. Mock circulatory loops were applied in 84 studies for aortic research, focusing on biomechanics, hemodynamics, and device testing, enhancing pre-clinical evaluation of therapies.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: