Key result
Carotid ultrasound detects ROSC with superior diagnostic accuracy vs. manual palpation and EtCO2.
Observational (n=88)
Assessor-blinded (manual palpation, ultrasonography, and EtCO2 assessors blinded to one another; team leader unblinded)
No
Answers are grounded in this paper and cite their sources.
Compares pulse detection methods in cardiopulmonary arrest, indicating 2D carotid ultrasound may be more effective.
This study suggests that 2D carotid ultrasonography can be effectively utilized for detecting pulses in patients suffering cardiopulmonary arrest.
No takes yet. Share an insight, caveat, or question.
Gullu et al. (2026) conducted an observational in Cardiopulmonary arrest (n=88). 2D carotid ultrasonography vs. Manual pulse palpation and end-tidal carbon dioxide (EtCO2) was evaluated on Diagnostic accuracy (area under the ROC curve) for identifying return of spontaneous circulation (ROSC) during pulse check cycles compared with manual palpation (AUC difference 0.112, 95% CI 0.044 to 0.180, p=0.001). Bedside 2D carotid ultrasonography achieved higher accuracy for detecting ROSC than manual palpation and EtCO2.
Synapse has enriched 10 related papers. Consider them for comparative context: