Answers are grounded in this paper and cite their sources.
Systematic differences in pressure measurements reveal discrepancies between mercury and electronic barometers.
Australian observations of sea-level pressure at many closely collocated stations indicate that pressures measure by Key pattern mercury barometers under field operating conditions during the 1990s tended to be slightly lower than corresponding pressures measured by electronic barometers (Vaisala PA11A and DPA25) when pressures were high, and vice versa. The observed effect is unlikely to have arisen by chance. The median size of the effect (mercury minus electronic) ranged from about +0.3 hPa when the observed pressure was low, to about -0.4 hPa when the pressure was high, with the lowest and highest percentiles used as thresholds.
No takes yet. Share an insight, caveat, or question.
Seaman et al. (2000) studied this question.