Key result
Endoscopic biopsy forceps safely extract a 20 cm retained epicardial pacing wire from the SMA.
Why the study?
There are no established clinical guidelines on the management or monitoring of retained temporary epicardial pacing wires, which are sometimes left in situ and can lead to rare complications.
Case Report (n=1)
No
Endoscopic biopsy forceps advanced through a steerable sheath can be successfully used as an alternative percutaneous technique to retrieve partially endothelialized migrated temporary epicardial pacing wires from deep vasculature.
May offer a percutaneous option for rare migrated pacing wire retrieval; hypothesis-generating and should not yet change practice.
Introduction: Temporary epicardial pacing wires (TEPWs) are utilized for arrhythmia management in postoperative cardiac surgery. TEPWs that cannot be removed are sometimes left in situ, which can lead to rare complications such as vessel stenosis and thrombosis. This case report describes the use of small biopsy forceps advanced to the superior mesenteric artery (SMA) through a steerable sheath to remove a partially endothelialized TEPW. Case Presentation: A 66-year-old man with a history of orthotopic heart transplantation presented for routine follow-up 2 years post-transplant. Imaging revealed a linear foreign object extending from the descending aorta into the SMA. The partially endothelialized object was successfully retrieved via percutaneous femoral access using an 8.5-Fr steerable sheath to advance endoscopic biopsy forceps, followed by a trilobed snare. The retrieved object measured 20 cm × 0.1 cm and was confirmed to be a retained TEPW. Post-procedural angiography showed no abnormalities, and the patient was discharged without complication. Clinical Discussion: Although a rare occurrence, there are no established clinical guidelines on the management or monitoring of retained TEPWs to avoid potential complications. In this report, the main concern was bowel ischemia, which urged object retrieval. Catheter snares are the preferred tools for intravascular foreign body retrieval. However, in this case, an uncommon approach involving a steerable sheath to advance endoscopic biopsy forceps into deep vasculature was successfully employed to retrieve the partially endothelialized wire. Conclusion: This case highlights an alternative retrieval technique for retained TEPWs and underscores the need for clinical guidelines to manage asymptomatic cases and prevent serious complications.
No takes yet. Share an insight, caveat, or question.
Cano et al. (2026) conducted a case report in Retained temporary epicardial pacing wire (n=1). Percutaneous retrieval using steerable sheath and endoscopic biopsy forceps was evaluated on Successful retrieval of the retained TEPW. Percutaneous retrieval using a steerable sheath and endoscopic biopsy forceps successfully removed a 20 cm migrated temporary epicardial pacing wire from the superior mesenteric artery.