Key result
Limus DCBs match paclitaxel-coated balloons for target lesion revascularization in in-stent restenosis.
Why the study?
Do limus drug-coated balloons reduce target lesion revascularization and failure compared to paclitaxel-coated balloons in patients with in-stent restenosis?
Meta-Analysis (n=1,208)
Do limus drug-coated balloons reduce target lesion revascularization and failure compared to paclitaxel-coated balloons in patients with in-stent restenosis?
Answers are grounded in this paper and cite their sources.
Limus-coated balloons demonstrate comparable clinical and angiographic efficacy and safety to paclitaxel-coated balloons for the treatment of in-stent restenosis at 12 months.
Background There is a significant trend in the use of drug coated balloons (DCBs) for the treatment of in-stent restenosis (ISR). However, there is a lack of robust comparative data between –limus drug coated balloons (DCBs) vs paclitaxel coated balloons (PCBs) on the efficacy and safety in treating ISR. Aims The objective of this systematic review and meta-analysis was to compare the efficacy and safety of -limus DCBs vs PCBs in terms of clinical and angiographic outcomes during a 12-month follow-up. Methods Following PRISMA guidelines, we systematically explored PubMed, SCOPUS, and Cochrane databases up to August 9, 2024, for studies comparing –limus DCBs vs PCBs in terms of safety, efficacy and angiographic outcomes in treating ISR. The primary outcomes were the incidence of clinically driven target lesion revascularization (TLR) and failure (TLF). Secondary endpoints were major adverse cardiovascular events (MACE) and angiographic findings during follow up. Results Data from six RCTs, including a total of 639 patients treated with limus DCBs and 569 with PCBs for ISR, were analyzed with a mean follow-up of 12 months. In this analysis, all six RCTs reported on TLR incidence, showing no significant difference between the limus DCB and PCB groups (14% vs. 11.4%, RR: 1.16, 95% CI: 0.82-1.64, I2=14%). Similarly, TLF rates were comparable between the two groups (15% vs. 14%, RR: 1.14, 95% CI: 0.86-1.53, I2=0%). Procedural success rates were high and similar (limus DCB: 100% vs. PCB: 99.5%). No significant differences were observed in MACEs (16.4% vs. 13.5%, RR: 1.11, 95% CI: 0.84-1.46, I2=0%), all-cause mortality (1.8% vs. 1.4%, RR: 1.25, 95% CI: 0.50-3.08, I2=0%), cardiac death (1.4% vs. 1%, RR: 1.19, 95% CI: 0.42-3.41, I2=0%), or target vessel myocardial infarction (TVMI) (0.9% vs 1%; RR: 0.58; 95% CI: 0.20-1.67, I2=0%). Angiographic outcomes showed no significant difference in post-intervention minimum luminal diameter (MLD) (SMD: +0.06, 95% CI: -0.07 to 0.18, I2=0%) and binary restenosis (19.5% vs 12.9%; RR: 1.45; 95% CI: 0.77-2.71, I2=63%) at follow-up between the groups. The risk of late lumen loss (LLL) was also comparable between limus DCB and PCB for in-segment analysis (SMD: 0.02, 95% CI: -0.18 to 0.23; I2=32%) and for in-lesion (SMD:-0.03, 95% CI: -0.31 to 0.24; I2=27%). Low heterogeneity was observed across the studies. Conclusion Our findings suggest that limus-DCBs are equally effective and safe as PCBs for treating ISR, demonstrating non-inferiority in both clinical and angiographic outcomes at 12 months post-intervention.
No takes yet. Share an insight, caveat, or question.
Sagris et al. (2025) conducted a meta-analysis in in-stent restenosis (ISR) (n=1,208). limus drug-coated balloons (DCBs) vs. paclitaxel-coated balloons (PCBs) was evaluated on clinically driven target lesion revascularization (TLR) (RR 1.16, 95% CI 0.82-1.64). Limus drug-coated balloons were noninferior to paclitaxel-coated balloons for in-stent restenosis, with similar target lesion revascularization rates.
Synapse has enriched 10 related papers. Consider them for comparative context: