Key result
Novel IVUS-based plaque index reclassifies CAD patterns in ~55% of visually assessed cases.
Why the study?
Does quantitative IVUS analysis using CPBi correlate with physiological CAD patterns and improve disease phenotyping compared to visual assessment?
Observational (n=123)
Does quantitative IVUS analysis using CPBi correlate with physiological CAD patterns and improve disease phenotyping compared to visual assessment?
Answers are grounded in this paper and cite their sources.
Quantitative plaque burden analysis using CPBi derived from IVUS is feasible and correlates with physiological atherosclerosis severity, potentially improving CAD phenotyping over visual assessment.
Background Intravascular ultrasound (IVUS) shows the location and burden of coronary artery disease (CAD) but is traditionally limited to the segment level, preventing the characterization of vessel-level CAD patterns based on plaque distribution, which impacts clinical outcomes. We aim to characterize and correlate the morphological and physiological patterns of CAD through quantitative IVUS analysis. Methods In this ASET JAPAN sub-study, pre- and post-percutaneous coronary intervention (PCI) IVUS and angiography were analyzed. Plaque burden was quantified per millimeter on the pre-PCI IVUS. After filtering out plaque burden <40%, CPB curves were generated to visualize morphological patterns. CPBi, a continuous metric derived from the CPB curves, was calculated to represent morphological patterns, with lower values indicating diffuse disease. Physiological CAD patterns were characterized by Murray law-based quantitative flow ratio (μFR)-derived pullback pressure gradient (PPG). Percentage reclassification was analyzed by comparing CPBi-derived CAD patterns with those derived from visual assessment and μFR-derived PPG.) (FigA). Results A total of 130 vessels (8101mm) from 123 patients were analyzed. The CPBi 0.45[IQR: 0.32-0.58] correlated well with the PPG 0.69 [0.61-0.79] (r=0.35, p<0.001) and post-PCI μFR (r=0.22, p=0.01). (FigB) Vessels with diffuse morphological patterns had significantly higher percent atheroma volume, lower pre-PCI μFR, and received longer stents. CPBi reclassified 55.4% of visually assessed disease patterns and 46.2% of μFR-derived physiological patterns. (FigC) Conclusions Quantitative plaque burden analysis of the entire IVUS is feasible with machine learning. The morphological patterns of coronary atherosclerosis can be visualized with CPB curves and quantified with CPBi, which is associated with atherosclerosis severity and hemodynamics. Future studies need to validate the potential clinical implications of CPB analysis.
No takes yet. Share an insight, caveat, or question.
Tsai et al. (2025) conducted an observational in Coronary artery disease (n=123). Cumulative plaque burden index (CPBi) vs. Visual assessment and μFR-derived PPG was evaluated on Correlation between CPBi and μFR-derived pullback pressure gradient (PPG) (r=0.35, p=<0.001). The cumulative plaque burden index (CPBi) correlated with μFR-derived pullback pressure gradient and reclassified 55.4% of visually assessed disease patterns.
Synapse has enriched 10 related papers. Consider them for comparative context: