Key result
LVAD implantation led to non-significant improvements in microcirculatory parameters such as TVDcap, while post-LVAD red blood cell velocity correlated with eGFR.
Why the study?
Does LVAD implantation improve sublingual microcirculatory parameters and are these changes related to the development of acute kidney injury in adult heart failure patients?
Observational (n=30)
Does LVAD implantation improve sublingual microcirculatory parameters and are these changes related to the development of acute kidney injury in adult heart failure patients?
Answers are grounded in this paper and cite their sources.
Sublingual microcirculatory parameters do not significantly change immediately after LVAD implantation and do not predict the development of acute kidney injury, though red blood cell velocity correlates with eGFR.
Background Acute kidney injury (AKI) is frequent following left ventricular assist device (LVAD) implantation and related to worse outcomes. Albeit LVAD implantation usually restore the secondary organ perfusion in patients with end-stage heart failure (HF), microcirculatory changes at renal level are unknown. Purpose We aimed to assess the changes in sublingual microcirculatory parameters after LVAD implantation in relation to the development of AKI. Methods We recruited 30 consecutive adult HF patients who underwent LVAD implantation. Sublingual microcirculation was assessed via a handheld video microscope (CytoCam hardware) before and within the same day after LVAD implantation. Microcirculatory parameters analyzed included total vessel density of capillaries (TVDcap), functional capillary density (FCD), and proportion of perfused vessels (PPV) as well as red blood cell velocity (RBCv). KDIGO criteria were used for AKI definition and classification. Results The mean age of the study population was 55.4 ±13.6 years, with the majority males (86.7%). The etiology of HF was ischemic heart disease in 17/30 (56.6%) cases, with destination therapy in 10 (33.3%) patients. HeartMate 3 was implanted in 22 (73.3%) cases, rest with HeartMate II. Although hemoglobin level reduced after implantation (7.8±1.1 mmol/L vs. 6.9±0.8;p<0.001), the microcirculatory parameters showed some improvements post LVAD but none of them statistically significant: pre-LVAD values of TVDcap (17.6±3.8 vs. 18.8±3,3; p=0.162), FCD (16.7±3.4 vs. 18.1±3.1; p=0.100), PPV (95.4±0.04 vs.96.5±0.020; p=0.317) and RBCv (330.7±74.0 vs. 353.5±26.1; p=0.335). AKI occurred in 23 (76.7%) patients during hospitalization, with ten (33.3%) cases of stage 1, eight (26.6%) cases of stage 2, and five (16.6%) cases of stage 3 AKI. Pre- and post-LVAD microcirculatory parameters were comparable among patients with and without AKI. Only post-LVAD RBCv had moderate correlation with post-LVAD estimated glomerular filtration rate (eGFR) (r= -0.400; p=0.035), while other microcirculation parameters had no significant correlation (Figure). Conclusion LVAD implantation leads to slight improvements in microcirculatory parameters, with significant correlation between post-LVAD red blood cell velocity (RBCv) and eGFR. Further research in larger patient groups is needed to determine whether incident AKI is associated with, and can be predicted by microcirculatory measurements.
No takes yet. Share an insight, caveat, or question.
Sener et al. (2025) conducted an observational in Heart failure (n=30). LVAD implantation vs. Pre-LVAD baseline was evaluated on Total vessel density of capillaries (TVDcap) (p=0.162). LVAD implantation led to non-significant improvements in microcirculatory parameters such as TVDcap, while post-LVAD red blood cell velocity correlated with eGFR.
Synapse has enriched 10 related papers. Consider them for comparative context: