Key result
Multiplanar TOE estimates LV volume more accurately than biplane angiography, showing ~4% bias vs. 11%.
Why the study?
Biplane angiographic and transthoracic echocardiographic volume calculations are unreliable in the presence of aneurysmatic distortions, whereas multiplane transoesophageal echocardiography has the potential to image irregular cavity forms more accurately.
Does multiplanar transoesophageal echocardiography improve the precision of left ventricular volume calculations compared to standard biplane angiography in normal and aneurysmatic left ventricular models?
Does multiplanar transoesophageal echocardiography improve the precision of left ventricular volume calculations compared to standard biplane angiography in normal and aneurysmatic left ventricular models?
Three-dimensional volume calculation using a multiplanar transoesophageal echoprobe and the disc-summation method provides highly precise left ventricular volume measurements unaffected by aneurysmatic geometry or transducer position in vitro, outperforming standard biplane angiography.
Answers are grounded in this paper and cite their sources.
May enhance LV volumetry in aneurysmal geometries; leaves open in vivo validation before clinical use.
BACKGROUND: Biplane angiographic and transthoracic echocardiographic volume calculations have shown to be sufficiently reliable in symmetric hearts; however, they are unreliable in the presence of aneurysmatic distortions. Multiplane transoesophageal echocardiography offers unobstructed cross-sectional views of the heart from one stable transducer position with the potential of imaging irregular cavity forms more accurately. It was the purpose of this in vitro study to compare the precision of multiplanar transoesophageal echocardiography to that of biplane angiography in determining left ventricular volumes, especially in aneurysmatic models. METHODS: Seven silicon rubber models of the left ventricle from post-mortem specimens (four with aneurysms) were filled with 30 different volumes (range 153-256 ml, 197 +/- 30 ml). Echocardiographic cross-sections (20 degree rotational steps) were obtained from different transducer positions, utilizing a multiplanar probe with a central rotational axis. Volumes were calculated using the disc-summation method. For comparison the same volumes were determined by standard biplane angiography. The minimum number of echo cross-section necessary to optimize precision was analysed by calculating volumes for each increasing equidistant rotational step. RESULTS: Linear correlation between measured volume using a multiplanar transoesophageal echoprobe and true volume was high (r = 0.97) and significantly better than for biplane angiography (r = 0.88; P < 0.001). Measurement bias and imprecision were also significantly lower with multiplanar echocardiography than with biplane angiography (3.9 +/- 7.1% vs 11.1 +/- 15.4%, and 2.0 +/- 3.7% vs 5.9 +/- 8.3%; P < 0.001). Precision of biplane angiographic volume measurements was significantly influenced by the presence of aneurysmatic distortions. Multiplanar echo volumes, however, were not influenced by left ventricular geometry and transducer positions. Nine echo cross-sections provided optimal precision. CONCLUSIONS: Three-dimensional echocardiographic volume calculations using a multiplanar transoesophageal echoprobe and the disc-summation method provide precise measurements unaffected by left ventricular geometry and transducer position in an in vitro setting. Standard biplane angiography is significantly less precise.
No takes yet. Share an insight, caveat, or question.
Krebs et al. (1996) studied Left ventricular volume and aneurysmatic distortions (in vitro post-mortem models) (n=7). Multiplanar transoesophageal echocardiography (using disc-summation method) vs. Standard biplane angiography was evaluated on Precision and linear correlation of left ventricular volume calculations compared with true volume (r = 0.97 vs r = 0.88, p=<0.001). Multiplanar transoesophageal echocardiography correlated better with true LV volume than biplane angiography with lower bias.