Demonstrates a novel arc fault detection system using a TDDA-CNN model, improving accuracy in various load conditions.
Low-voltage AC series arc faults are a leading cause of electrical fires, posing significant risks to life and property. While artificial intelligence-based detection methods have achieved high accuracy, they often suffer from limited interpretability and are typically tailored to specific loads, thus struggling to adapt to the diverse and dynamic load conditions in residential environments. To address these limitations, this paper proposes a novel interpretable arc fault detection model based on prototype learning with a hybrid attention mechanism. Specifically, we design a Tri-Domain Dynamic Attention (TDDA) module that integrates time-domain, frequency-domain, and temporal derivative information, and embed it into a Convolutional Neural Network (CNN) for enhanced feature extraction. Visual prototypes are constructed from sample characteristics, forming a tri-domain arc fault prototype set. A dedicated non-arc prototype set is further introduced to refine the decision boundary and improve accuracy. The proposed model is validated through comprehensive experiments and hardware implementation on a dedicated test platform. Results demonstrate that our model achieves an accuracy of 99.65%, maintains over 99% accuracy across various single-load conditions, and exhibits high detection performance under complex multi-load scenarios.