February 8, 2026Expert Review of Cardiovascular Therapy0 citations

Temporal trends of cardiac implantable electronic devices (CIED) implantation in the Brazilian public health system: a 12-year real-world data study

View Full Paper
MMMiriam Allein Zago MarcolinoRRRodrigo Antonini RibeiroCPCarisi Anne Polanczyk

Key Result

Standardized CIED implantation rates declined in Brazil's public health system over 12 years, notably for pacemakers and CRT-P devices, despite rising total volume.

Key Points

  • This research aims to investigate the trends in CIED implantation within Brazil's public health system over 12 years.
  • Analyzed real-world data from the Brazilian public health system (SUS)
  • Examined rates of CIED implantation, including PM and CRT-P
  • Assessed regional differences in implantation trends
  • Overall CIED implantation rates increased, but standardized rates decreased
  • Notable decline in PM and CRT-P procedures
  • Regional disparities indicate uneven access to CIED therapies

Structured PICO

What are the temporal trends of cardiac implantable electronic device (CIED) implantation rates in the Brazilian public health system?

P
Population
Patients in the Brazilian public health system (SUS) undergoing cardiac implantable electronic devices (CIED) implantation over a 12-year period
I
Intervention
Cardiac implantable electronic devices (CIED) implantation, including pacemakers (PM) and cardiac resynchronization therapy pacemakers (CRT-P)
O
Outcome
Standardized CIED implantation rates and regional trends

Standardized CIED implantation rates in the Brazilian public health system have declined over 12 years, with divergent regional trends indicating a need for policies to ensure equitable access.

Abstract

Despite increasing volume, standardized CIED implantation rates declined in SUS, especially for PM and CRT-P. Divergent regional trends highlight the need for targeted health policies to ensure equitable access to advanced CIED therapies.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Marcolino et al. (2026) studied this question. Standardized CIED implantation rates declined in Brazil's public health system over 12 years, notably for pacemakers and CRT-P devices, despite rising total volume.