Key result
Peak-frequency mapping in AF provides superior stability across activation directions, avoiding omnipolar voltage's ~21% variation.
Why the study?
Low-voltage areas and peak frequency may help identify arrhythmogenic substrates in AF, but the impact of activation direction on these parameters has not been systematically examined.
Does activation direction (CS vs PSN pacing) impact omnipolar voltage and peak-frequency in the atria?
Does activation direction (CS vs PSN pacing) impact omnipolar voltage and peak-frequency in the atria?
Peak-frequency remains relatively stable across different pacing conditions compared to omnipolar voltage, offering a consistent marker of atrial substrate properties independent of activation direction.
Answers are grounded in this paper and cite their sources.
May confound voltage-based AF substrate mapping; leaves open peak-frequency as a direction-independent marker pending validation.
Background Low-voltage areas are strongly associated with arrhythmic substrates in atrial fibrillation (AF). Another parameter, peak frequency, reflecting electrogram sharpness, has been introduced as a novel marker to focus on near-field activation. A combination of these parameters may be important to show the arrhythmogenic substrates, but the impact of activation direction on these parameters has not been systematically examined. Purpose This study aims to investigate the impact of omnipolar voltage and peak-frequency in left atrium (LA) of AF patients, and right atrium (RA) in healthy animal model during pacing from two distinct atrial sites. Method A total of 10 AF patients and 16 healthy animals were included in this study. In each patient and animal, 3D-anatomical maps were composed during coronary sinus (CS) pacing and peri-sinus node (PSN) pacing. At each site, five beats were acquired during CS-pacing and PSN-pacing before moving the catheter to the subsequent sites. Both omnipolar voltage and peak-frequency during CS-pacing and PSN-pacing were compared. Results The AF patients included in the analysis had a mean age of 65.1 ±13.1years, 90% were male, and LA volume was 95.5±52.9 ml. None had structural heart disease. The mean omnipolar voltage was 2.18 mV during CS pacing and 2.43 mV during PSN pacing, with an average difference of 21.1% between the two sites. The mean peak-frequency was 353 Hz during CS pacing and 348 Hz during PSN pacing, showing a 3.5% change on average. The average difference between the pacing sites in omnipolar voltage was significantly greater than that of peak-frequency (p<0.001). A similar significant difference was observed in the animal RA, with the average difference between the pacing sites being 14.8% for omnipolar voltage and 2.2% for peak-frequency (p<0.001). Conclusions The omnipolar voltage varied significantly depending on the pacing sites, whereas peak-frequency remained relatively stable across different pacing conditions. This stability in peak-frequency offers novel insights as a consistent marker of atrial substrate properties, independent of pacing-induced variations.
No takes yet. Share an insight, caveat, or question.
Masumura et al. (2025) studied this question. Omnipolar voltage varied by 21.1% during CS vs PSN pacing in AF patients, while peak-frequency changed only 3.5%, showing peak-frequency's stability across activation directions.
Synapse has enriched 10 related papers. Consider them for comparative context: