Key result
Primary prevention ICD therapy shows no total mortality benefit in women, unlike in men.
Why the study?
Routine primary prevention ICD implantation in women has been accepted as standard of care based on outdated, male-preponderant trial data despite a lack of unequivocal scientific proof of benefit in women.
Does primary prevention implantable cardioverter-defibrillator implantation reduce total mortality in women with heart failure receiving contemporary medical and device therapy?
Does primary prevention implantable cardioverter-defibrillator implantation reduce total mortality in women with heart failure receiving contemporary medical and device therapy?
This review challenges routine primary prevention ICD implantation in women with heart failure, highlighting lower sudden cardiac death risk, better response to CRT, higher device complication rates, and lack of demonstrated mortality benefit in female subgroups of landmark trials.
Answers are grounded in this paper and cite their sources.
Warrants caution against routine primary prevention ICDs in women with HF; challenges consensus and leaves open sex-specific trials.
Implantable cardioverter-defibrillators (ICDs) used in the primary prevention setting have been shown to prevent sudden cardiac death (SCD) and reduce total mortality. However, the evidence supporting guideline recommendations for the ICD dates from the late 1990s and early 2000s. With improvements in pharmacological and device therapy, earlier and more aggressive cardiovascular prevention, and prompt coronary intervention, there has been a gradual and substantial reduction in SCD risk over the last two decades in patients with heart failure,1 limiting the absolute benefit of the ICD and increasing the number needed to treat to save one life. One may even reasonably speculate whether the results of ICD randomized trials would be the same if conducted in the current era of heart failure management. There is especially a need to revisit the current status of routine primary prevention ICD implantation in women, which has been accepted as a standard of care despite a lack of unequivocal scientific proof of benefit in this population. We critically review current evidence and highlight potential issues with ICD implantation in women, including (i) extrapolation of results derived from male-preponderant studies, (ii) relatively outdated data, not reflecting current state of heart failure care, and (iii) relatively weak evidence with respect to benefit in women. Women have a lower susceptibility to ventricular arrhythmia and arrhythmic death compared with men irrespective of the presence of coronary artery disease.2 A lower proportion of women’s deaths are sudden throughout a spectrum of mortality risk regardless of heart failure severity.3 In fact, the lifetime risk of SCD in women is significantly lower than in men across all age strata, and women presenting with out of hospital cardiac arrest or dying of SCD are typically 10–20 years older than their male counterparts. Sports-related SCD in women is dramatically less common that in men at any age strata.4,5 Importantly, they are also more likely to present with non-shockable rhythms, which are not amenable to ICD therapy. Less extensive coronary artery disease, lesser myocardial fibrosis, lower susceptibility to triggers of ventricular arrhythmia, and differences in autonomic function due to hormonal effects may all contribute to the lower observed risk of arrhythmic death in women. Next, women are better responders to cardiac resynchronization therapy (CRT) than men, and this increasingly used therapy reduces the risk of ventricular arrhythmias and SCD, independent of a defibrillator. The incidence of SCD among CRT recipients has declined considerably over the years regardless of the defibrillator,6 and the benefit of adding ICD to CRT has never been proven in the primary prevention context regardless of sex.7 Furthermore, women are more likely to be diagnosed with non-ischaemic dilated cardiomyopathy, in which case the risk of SCD is already markedly low when patients are on goal-directed HF medications (including beta-blockers, mineralocorticoid receptor antagonists and combined neprilysin inhibition with an angiotensin II receptor blocker) and CRT in appropriate candidates. In ICD studies enrolling non-ischaemic patients exclusively (DEFINITE and DANISH) or even partly (SCD-HeFT), no significant benefit or trend for benefit was seen in the female subgroup. Finally, women are more susceptible to long-term device-related complications, which may contribute to morbidity/mortality, negating the benefit of ICD to some extent, as the addition of defibrillator functionality is known to increase the risk of complications requiring surgical intervention.8,9 A meta-analysis pooling the results of six major trials assessing the benefit of the primary prevention ICD according to sex revealed that, while the ICD was effective in reducing mortality in men [hazard ratio (HR) 0.75, 95% confidence interval (CI) 0.67–0.84], hazard ratios were heterogeneous in women, with overall no signal for a reduction in total mortality (HR 0.93, 95% CI 0.68–1.27).10 When the COMPANION trial, in which the survival advantage seen in the ICD group was due at least partly to the presence of CRT, was excluded from the analysis, the lack of effect in women was even more apparent (HR 1.01, 95% CI 0.73–1.39). A recent analysis of long-term outcomes in the SCD-HeFT trial also confirmed the apparent lack of benefit in women, which the original study had suggested.11 Data from observational studies are at times conflicting. In the European Comparative Effectiveness Research multicenter cohort study (EU-CERT-ICD), the use of primary prevention ICDs had no mortality benefit among women, although only 18% of patients in the study were women,12 whereas in the Swedish Heart Failure Registry, the association between ICD use and all-cause mortality was consistent in both men and women.13 In the latter study, given that the number of non-ICD patients was much higher than that of ICD patients, the use of propensity score matching resulted in the exclusion of many more non-ICD patients for whom a suitable control was not found. Therefore, the matched analysis estimated the treatment effect of the ICD in a population of patients who would more closely resemble those who typically get an ICD, with potentially fewer competing risks for mortality and an overall greater contribution from SCD (younger, with fewer comorbidities). The use of inverse probability of treatment weighting, which would estimate the treatment effect of the ICD in a population whose distribution of characteristics is similar to that found in all study subjects, would have been useful.14 Some arguments can be put forward on the basis of the aforementioned data. First, fresh randomized trials are needed to assess the presence and magnitude of benefit of the primary prevention ICD in heart failure patients in the context of present-day pharmacotherapies as well as CRT. This benefit should be assessed in terms of total mortality reduction and not merely SCD. The occurrence of ICD therapies is not a valid surrogate endpoint for total mortality or even SCD, as most ICD therapies are not truly life-saving, and this endpoint should not be used to assess whether the ICD is beneficial. Second, it is high time to rectify the poor representation of women, and randomized trials should increase the number of female participants. Women represented only 16% of the study cohort in MADIT-II, 23% in SCD-HeFT, and 28% in DANISH, leading to a gap of evidence between genders. Third, an appropriate sample size should be chosen, keeping in mind the lower risk of arrhythmic death in women, to allow adequate power and appropriate sex-specific conclusions. The low participation of female patients in ICD trials is a long-standing problem, but physicians and guidelines continue to extrapolate from results derived mainly from men to recommend routine ICD implantation in women despite lack of clear proof of mortality reduction (Figure 1). Conversely, the benefit of the ICD in men may have been relatively underestimated when looking at the data in total. It is evident that the data being used for decision-making are both outdated and also weak with respect to potential benefit in women. Hence, it can be strongly argued that true equipoise exists for new, well-designed randomized trials assessing the efficacy of primary prevention ICDs particularly in female patients in conjunction with current heart failure therapies. Primary prevention implantable cardioverter-defibrillator in women: need for fresh evidence. CRT, cardiac resynchronization therapy; DCM, dilated cardiomyopathy; ICD, implantable cardioverter-defibrillator; HF, heart failure; SCD, sudden cardiac death. Primary prevention implantable cardioverter-defibrillator in women: need for fresh evidence. CRT, cardiac resynchronization therapy; DCM, dilated cardiomyopathy; ICD, implantable cardioverter-defibrillator; HF, heart failure; SCD, sudden cardiac death. The Paris-SDEC activities are supported by the Institut National de la Santé et de la Recherche Médicale (INSERM), University of Paris, Assistance Publique-Hôpitaux de Paris, Fondation Coeur et Artères, Global Heart Watch, Fédération Française de Cardiologie, Société Française de Cardiologie, Fondation Recherche Medicale, and unrestricted grants from industrial partners (Medtronic, Abbott, Boston Scientific, MicroPort, Biotronik, and Zoll). Paris-SDEC Executive Committee is part of the ESCAPE-NET project (Horizon2020 programme). Conflict of interest: none declared. The opinions expressed in this article are not necessarily those of the Editors of the European Heart Journal or of the European Society of Cardiology.
No takes yet. Share an insight, caveat, or question.
Barra et al. (2020) conducted a review in Heart failure / primary prevention of sudden cardiac death in women. Implantable cardioverter-defibrillator (ICD) for primary prevention vs. Goal-directed heart failure medical therapy and/or cardiac resynchronization therapy without defibrillator was evaluated on Total mortality in women (pooled meta-analysis of 6 trials cited in review) (HR 0.93, 95% CI 0.68-1.27). Primary prevention ICD therapy in women showed no clear reduction in total mortality in a cited 6-trial meta-analysis, unlike in men.
Synapse has enriched 10 related papers. Consider them for comparative context: