Key result
Cardiac rehab linked to ~19% lower AF recurrence risk per ten sessions in CIED patients.
Why the study?
While cardiac rehabilitation decreases MACE in a dose-dependent fashion, its effect on AF burden and time to AF recurrence was unknown.
Does a higher number of completed cardiac rehabilitation sessions delay time to AF recurrence in patients with CIEDs and established AF?
Does a higher number of completed cardiac rehabilitation sessions delay time to AF recurrence in patients with CIEDs and established AF?
Greater participation in cardiac rehabilitation is associated with a dose-dependent delay in time to device-detected AF recurrence among patients with CIEDs.
Answers are grounded in this paper and cite their sources.
Should not yet change practice in CIED patients; leaves open a dose-response effect on AF recurrence pending randomized trials.
Background Cardiac rehabilitation (CR) has been shown to decrease major adverse cardiovascular events (MACE) in a dose-dependent fashion. Its effect on atrial fibrillation (AF) burden and time to AF recurrence is unknown. Purpose To determine the dose-response effect of completed CR sessions on AF burden and time to AF recurrence after completing CR. Methods A retrospective analysis was performed in patients with cardiovascular implanted electronic devices (CIEDs) enrolled in a large multisite clinical registry at an academic healthcare system in North Carolina who participated in at least one CR session. Daily physiological data (i.e., AF burden) were obtained from CIEDs over a 12-month period between September 2011 and September 2024. Multivariate Cox proportional hazards model was used to analyze the independent effect of the number of completed CR sessions on time to AF recurrence, defined as days to the first CIED-detected AF episode >6 minutes. Patients without AF recurrence during the observation period were censored at their last date with available recorded data. The model adjusted for age, sex, CIED type (pacemaker or loop recorder versus defibrillator), body mass index, history of AF ablation, systolic heart failure, previous percutaneous coronary intervention, valve disorders, diabetes mellitus, insurance status (private vs. public), and AF pattern (persistent vs. paroxysmal). The impact of completed CR sessions on AF burden was assessed by comparing the median daily AF burden over a 30-day window at baseline (0-30 days) and after completion of CR (335-365 days) using Mann–Whitney U test. Results There were 163 patients with daily CIED data and a prior diagnosis of AF who completed at least one CR session after device implantation. Because of incomplete data, 61 were excluded leaving a final study cohort of 102 patients [mean [SD] age, 74 [9.8] years; 27% female; 88% paroxysmal AF; 46% defibrillators]. The median number of completed CR sessions was 24 (range 1-36). During follow-up, 57 patients (55.88%) experienced AF recurrence. Multivariable Cox regression demonstrated that the number of completed CR sessions increased the time to AF recurrence in a dose-dependent fashion. For each additional CR session completed there was an associated 1.9% reduction in risk for AF recurrence (HR 0.9815; 95% CI: 0.9645 – 0.9989, p = 0.037). Thus, a patient who completed 10 more CR sessions than another patient would have a 19% lower risk of AF recurrence. However, the number of completed CR sessions did not significantly affect median AF burden at 30 days or 1 year. Conclusion In this large cohort of CIED patients with established AF, cardiac rehabilitation participation increased time to AF recurrence in a dose-dependent fashion with no upper threshold. These findings reinforce the importance of CR participation in secondary prevention and highlight the possibility that CR should be prescribed more widely and include patients with AF.
No takes yet. Share an insight, caveat, or question.
Mazzella et al. (2025) studied this question. Each additional cardiac rehab session reduced AF recurrence risk by 1.9%; 10 more sessions lowered risk by 19% in patients with implanted cardiac devices.
Synapse has enriched 10 related papers. Consider them for comparative context: