Key result
Novel balloon-in-basket PFA device shows high PVI effectiveness and excellent safety.
Why the study?
A novel balloon-in-basket catheter integrated into a mapping system may advance pulsed field ablation of AF with deeper lesions, less hemolysis, and promising initial clinical experience.
Does a balloon-in-basket pulsed field ablation system provide effective and safe pulmonary vein isolation in patients with symptomatic atrial fibrillation?
Does a balloon-in-basket pulsed field ablation system provide effective and safe pulmonary vein isolation in patients with symptomatic atrial fibrillation?
The novel balloon-in-basket pulsed field ablation system demonstrated high effectiveness for pulmonary vein isolation and excellent safety at 1 year in patients with paroxysmal and persistent atrial fibrillation.
BACKGROUND: A novel balloon-in-basket catheter integrated into a mapping system may advance pulsed field ablation (PFA) of atrial fibrillation (AF) with demonstrated deeper lesions, less hemolysis, and promising initial clinical experience. OBJECTIVES: The goal of this study was to assess the 1-year clinical outcomes of the balloon-in-basket PFA system. METHODS: The multicenter VOLT-AF IDE Clinical Study enrolled patients with symptomatic, paroxysmal (PAF), and persistent AF (PeAF) . Pulmonary vein isolation (PVI) was performed with the investigational system. The primary effectiveness endpoint was acute PVI and 12-month freedom from atrial arrhythmia, antiarrhythmic escalation/initiation, cardioversion, or repeat ablation. The primary safety endpoint was device- and/or procedure-related serious adverse events within 7 days of any ablation. Follow-up consisted of 12-lead electrocardiograms at discharge, 3 months, and 12 months; biweekly and symptomatic transtelephonic monitoring; and 24-hour Holter monitoring at 12 months. RESULTS: -VASc score was 2.3 ± 1.6. Left atrial catheter dwell time was 44.1 ± 18.1 minutes (including a 20-minute wait). A mean of 4.6 ± 0.9 applications were delivered per vein. Primary effectiveness was 81.1% (95% CI: 74.3%-86.3%) in PAF and 63.3% (95% CI: 55.1%-70.4%) in PeAF. Freedom from documented arrhythmia recurrence was 84.2% in the PAF group and 67.8% in the PeAF group. Primary safety events occurred in 1.9% of patients, with none in the PAF group. During redo ablation in 19 patients, 78.5% of pulmonary veins remained durably isolated. CONCLUSIONS: This multicenter trial reports high PVI-based effectiveness of the novel balloon-in-basket PFA device with excellent safety.(VOLT-AF IDE Clinical Study; NCT06223789).
No takes yet. Share an insight, caveat, or question.
Verma et al. (2026) studied Atrial fibrillation. Balloon-in-basket pulsed field ablation (PFA) system was evaluated on Acute PVI and 12-month freedom from atrial arrhythmia, antiarrhythmic escalation/initiation, cardioversion, or repeat ablation (95% CI 74.3-86.3). The novel balloon-in-basket pulsed field ablation system achieved primary effectiveness in 81.1% of patients with paroxysmal AF and 63.3% with persistent AF, with a 1.9% safety event rate.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: