Key result
Endo-aortic balloon occlusion was associated with a higher conversion rate to full sternotomy and longer cross-clamp time compared to transthoracic cross-clamping, with no differences in mortality or major complications.
Why the study?
Debate persists regarding the optimal aortic clamp occlusion strategy in minimally invasive mitral valve surgery, with limited comparative clinical data between transthoracic cross-clamping and endo-aortic balloon occlusion.
Does endo-aortic balloon occlusion reduce intra-operative complications and conversion to full sternotomy compared to transthoracic cross-clamping in adult patients undergoing elective minimally invasive mitral valve surgery?
Cohort (n=163)
No
Does endo-aortic balloon occlusion reduce intra-operative complications and conversion to full sternotomy compared to transthoracic cross-clamping in adult patients undergoing elective minimally invasive mitral valve surgery?
In minimally invasive mitral valve surgery, endo-aortic balloon occlusion is associated with longer cross-clamp times and higher rates of conversion to sternotomy compared to transthoracic cross-clamping, though both techniques demonstrate equivalent overall safety and mortality.
Answers are grounded in this paper and cite their sources.
May favor transthoracic cross-clamping to limit conversions in minimally invasive mitral surgery; leaves open optimal technique in randomized trials.
Background and Objectives: Minimally invasive surgery (MIS) has become a cornerstone approach in cardiac surgery. A debate persists regarding the optimal aortic clamp occlusion strategy, with limited comparative data. The two principal strategies, which are transthoracic cross-clamping (TTCC) and endo-aortic balloon occlusion (EABO), offer distinct advantages, but comparative clinical data remain limited. This study compares the two techniques in terms of procedural safety and early outcome. Materials and Methods: This single-center retrospective study included consecutive adult patients undergoing elective MIS via video-assisted right mini-thoracotomy between 2012 and 2018 for mitral valve surgery. Tricuspid repair, atrial fibrillation and redo surgery were included in the final cohort. Aortic occlusion was performed with transthoracic cross-clamping (TTCC) or endo-aortic balloon occlusion (EABO). Primary endpoints were intra-operative complications and the rate of conversion to full sternotomy; secondary outcomes were overall mortality and Society of Thoracic Surgeons (STS)-defined comorbidities. Results: A total of 163 patients were analyzed (TTCC: n = 99, 60%; EABO: n = 64, 40%). While both techniques demonstrated equivalent safety profiles (overall mortality: 0%), EABO was associated with higher conversion to full sternotomy [(n = 7, 10.9%) vs. TTCC (n = 1, 1.3%), p = 0.016]. In a generalized estimation equations (GEE) model, no patient-level covariate predicted conversion, suggesting technical or procedural factors as the primary contributors. In addition, EABO was associated with longer cross-clamp time [median: 87 min (IQR: 73, 100) vs. TTCC median: 77 min (IQR: 65.5, 87.5), p = 0.03]. Stroke, acute kidney injury, respiratory failure, reoperation and wound infection did not differ significantly; also, hospital stay was similar between groups. Conclusions: In this single-center series, EABO showed longer operative times and a higher conversion rate to sternotomy, but without excess mortality or major complications. This may be correlated with the initial learning phase and redo cases; further comparison is needed to assess the benefits of EABO.
No takes yet. Share an insight, caveat, or question.
Shazly et al. (2026) conducted a cohort in Adult patients undergoing elective minimally invasive mitral valve surgery via right mini-thoracotomy, including redo surgeries and concomitant tricuspid repair or atrial fibrillation ablation (n=163). Endo-aortic balloon occlusion (EABO) vs. Transthoracic cross-clamping (TTCC) was evaluated on Intra-operative complications (aortic dissection, device migration) and conversion rate to full sternotomy (p=0.016, p=0.016). Endo-aortic balloon occlusion was associated with a higher conversion rate to full sternotomy and longer cross-clamp time compared to transthoracic cross-clamping, with no differences in mortality or major complications.
Synapse has enriched 10 related papers. Consider them for comparative context: