The clinical course of conduction disturbances after permanent pacemaker implantation based on the type of TAVI valve remains unclear.
Does the type of TAVI valve (self-expandable vs. balloon-expandable) affect the recovery of autologous AV conduction and ventricular pacing ratio in patients requiring permanent pacemaker implantation?
Observational (n=480)
No
Does the type of TAVI valve (self-expandable vs. balloon-expandable) affect the recovery of autologous AV conduction and ventricular pacing ratio in patients requiring permanent pacemaker implantation?
Answers are grounded in this paper and cite their sources.
While the incidence of permanent pacemaker implantation is similar between TAVI valve types, self-expandable valves are associated with a significantly higher rate of autologous AV conduction recovery and lower ventricular pacing dependency at 1 month compared to balloon-expandable valves.
Background In some patients, transcatheter aortic valve implantation (TAVI) is associated with conduction disturbances, necessitating permanent pacemaker implantation (PMI). The clinical course of conduction disturbances after PMI, based on the type of TAVI valve, remains unclear. Therefore, the present study aimed to evaluate the effects of different types of TAVI valves on the clinical course of conduction disturbances. Methods In total, 480 patients, including 230 with self‐expandable (SE) valves and 250 with balloon‐expandable (BE) valves, who underwent TAVI between January 2016 and December 2024, were enrolled in this study. The characteristics of patients who required PMI and the changes in the ventricular pacing ratio were compared. Results There was no significant difference in PMI factors depending on the type of valve. Computed tomography (CT) images showed that the length of the membranous septum (MS) in the PMI group did not differ from the length of the MS in the non‐PMI group. There was a significant difference in improvement in autologous AV conduction between the SE and BE groups at PMI time (SE group vs. BE group; 11/15 [66.7%] vs. 3/11 [27.3%], p = 0.047). At 1 month follow‐up, the SE group improved significantly compared to the BE group (SE vs. BE; 14/15 [93.3%] vs. 4/11 [33.3%], p = 0.002). Conclusion Restoration of autologous AV conduction and subsequent decrease in ventricular pacing ratio were more likely in the SE group and less variable in the BE group. This result indicates that PM dependency can be reduced by using an extended AVD setting or AVH.
No takes yet. Share an insight, caveat, or question.
Fukuoka et al. (2026) conducted an observational in Patients undergoing transcatheter aortic valve implantation (TAVI) with implanted permanent pacemaker; comparison of valve types (self-expandable vs. balloon-expandable) (n=480). Self-expandable (SE) TAVI valve vs. Balloon-expandable (BE) TAVI valve was evaluated on Incidence of permanent pacemaker implantation (PMI) and improvement of intrinsic atrioventricular (AV) conduction with changes in ventricular pacing ratio at 1 month follow-up (p=0.540 for PMI incidence (no significant difference); Improvement in AV conduction 93.3% vs. 36.4%, p=0.002, p=0.540 for PMI incidence; 0.002 for AV conduction improvement).
Synapse has enriched 10 related papers. Consider them for comparative context: