Key result
FLOWer filter in TAVI is linked to ~85% fewer 30-day major adverse events versus benchmarks.
Why the study?
Embolic events are life-threatening complications of TAVI with clinically relevant stroke rates of 2%-4%, prompting evaluation of the safety and effectiveness of the novel FLOWer embolic protection device.
Does the FLOWer embolic protection device safely capture debris and reduce major adverse events in patients undergoing TAVI?
Does the FLOWer embolic protection device safely capture debris and reduce major adverse events in patients undergoing TAVI?
The novel FLOWer embolic protection device is safe and feasible during TAVI, effectively capturing debris and demonstrating a low 30-day major adverse event rate compared to historical benchmarks.
Answers are grounded in this paper and cite their sources.
Suggests low MAEs with high debris capture using FLOWer in TAVI; leaves open benefit versus controls in randomized trials.
Background Embolic events are life‐threatening complications of transcatheter aortic valve implantation (TAVI) with clinically relevant stroke rates of 2%–4%. Aims This study aims to evaluate the safety and effectiveness of FLOWer, a novel embolic protection device (EPD) used in TAVI procedures. Methods Data on the FLOWer device were obtained from its CE‐mark clinical trial (the NAUTILUS study, NCT 04704258). Safety outcomes were the 30‐day rate of major adverse events (MAEs, including all deaths, ischemic strokes, and acute kidney injury), while effectiveness data consisted of the number of particles captured by the filter during the procedure. These data were compared with benchmark values from the EPD literature. In addition, the total number (TNL) and volume (TVL) of new brain lesions were evaluated. Results A total of 52 intention‐to‐treat (ITT) patients were considered, 45 of whom were per protocol (PP) patients. The rate of 30‐day MAEs for the PP population was 2.2% (1/45% vs. 14.3%, p = 0.0082); no strokes were observed. The median number of captured debris larger than 60 μm was 213 (IQR: 128−315 vs. 46.1, p < 0.0001), and larger than 150 μm, 105 (IQR: 60−190 vs. 41.6, p < 0.0001). The median TVL and TNL per patient were 291.7 mm 3 (IQR: 98.5−630.7 mm 3 ) and 4.5 mm 3 (IQR: 2.0−8.3 mm 3 ), respectively. Conclusions The use of FLOWer during TAVI was found to be feasible and safe, with a low incidence of MAEs and a reduced number and volume of new brain lesions. The significant amount of debris captured compared to similar devices demonstrates effective device performance.
No takes yet. Share an insight, caveat, or question.
Sorropago et al. (2026) studied this question. FLOWer filter in TAVI reduced 30-day major adverse events to and captured median 213 debris >60μm vs 46.1 in benchmarks.
Synapse has enriched 10 related papers. Consider them for comparative context: