Answers are grounded in this paper and cite their sources.
Demonstrates the effective use of microlaryngeal endotracheostomy tubes for perioperative airway management, suggesting a practical solution in emergencies.
Three years ago, a theoretical idea dawned whether microlaryngeal endotracheal tube can convert cuffless tracheostomy tube into microlaryngeal endotracheostomy tube during logistical and/or medical emergency wherein otorhinolaryngologist is either not available for or not amenable with a time-sensitive plan for safely exchanging cuffless tracheostomy tube with cuffed tracheostomy tube to meet the time-sensitive need for perioperative positive pressure ventilation with concurrent need for perioperative airway protection against tracheobronchial aspiration. At that time, during a schematic simulation of microlaryngeal endotracheostomy tube with 5.0-mm internal diameter (ID) and 6.9-mm outer diameter (OD) microlaryngeal endotracheal tube across a 7.5-mm ID cuffless tracheostomy tube [Figure 1], it was felt that an adult-size bulky cuff could be difficult to pass across in situ cuffless tracheostomy tube with final positioning of microlaryngeal endotracheal tube tip being potentially too close to carina after making it through. Although perioperative airway management specialists can consider the use of an airway exchange catheter for safe exchange of cuffless tracheostomy tube with cuffed tracheostomy tube without risking loss of airway,[1-3] perioperative exchange of tracheostomy tube may not always be feasible, depending on the patient’s surgical airway anatomy and the airway procedure’s technical difficulty. Thus, somehow, a recent logistical perioperative urgency warranted the utility of microlaryngeal endotracheostomy tube with 4.0-mm ID and 5.6-mm OD microlaryngeal endotracheal tube across 7.5-mm ID cuffless tracheostomy tube,[4,5] wherein, despite adult size bulky cuff, this recent 4.0-mm ID tube insertion across 7.5-mm ID tube in vivo was smoother as compared to in vitro schematic simulation with 5.0-mm ID tube insertion across 7.5-mm ID tube 3 years ago. As depicted in Figure 2 (and hereby shared after patient’s consent), perioperative management with this depicted microlaryngeal endotracheostomy tube was uneventful to safely complete a short duration laparoscopic surgery for gastrostomy tube placement whereafter the well-lubricated microlaryngeal endotracheal tube inserted during induction of anaesthesia across the pre-existent cuffless tracheostomy tube was removed after emergence from anaesthesia, thus leaving behind the pre-existent cuffless tracheostomy tube in situ for post-operative recovery of tracheostomised patient on room air. Anyhow, the only concern preventing microlaryngeal endotracheostomy tube from becoming a norm to manage logistical and/or medical emergency is a perioperative potential risk for tracheostomy tube’s blockade with inadequately lubricated microlaryngeal tube and/or its inadequately deflated adult-size bulky cuff traversing across tracheostomy tube, whereafter emergent intervention by otorhinolaryngologist might be warranted to prevent tracheostomy tube’s blockade turning into an airway catastrophe.Figure 1: In vitro microlaryngeal endotracheostomy tube (schematic simulation). ID: Internal diameter, OD: Outer diameterFigure 2: In vivo microlaryngeal endotracheostomy tube (de-identified patient)Authors’ contributions MI: Contributed to de-identified case-consent performance, manuscript editing and manuscript review; DG: Contributed to concept, simulation, manuscript preparation, manuscript editing and manuscript review. Financial support and sponsorship Nil. Conflicts of interest There are no conflicts of interest.
No takes yet. Share an insight, caveat, or question.
Ismaeil et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: