Key result
Inappropriate VAD selection is not linked to increased complications despite only ~43% appropriate peripheral use.
Observational (n=161)
No
There is a high prevalence of inappropriate peripheral vascular access device selection in hospitalized patients, highlighting the need for improved adherence to selection guidelines.
Answers are grounded in this paper and cite their sources.
Inappropriate peripheral VAD selection appears safe; leaves open value of stricter guideline adherence in randomized trials.
INTRODUCTION: Vascular access devices (VADs) play a critical role in clinical practice, facilitating the administration of medications, fluid therapy, and parenteral nutrition. Nevertheless, improper selection of VADs can result in various complications, escalate healthcare costs, and significantly impact patients' experience. This study seeks to evaluate the appropriateness of VAD selection in contemporary clinical practice. METHODS: A prospective observational pilot study was conducted between September 1st and December 31st, 2023, in two medical wards at Careggi University Hospital, Florence, Italy. Data on VAD type, insertion, maintenance, and complications were collected. The primary outcome was the appropriate selection of central VADs (CVADs) and peripheral VADs (PVADs) as recommended by the most recent international guidelines and consensus documents. RESULTS: A total of 322 VADs were inserted in the considered period, out of which 23 (7.1%) were CVADs and 299 (92.9%) were PVADs. Peripherally Inserted Central Catheter (PICC, n = 10; 43.5%) was the most represented CVAD, followed by ports (n = 6; 26%), Centrally Inserted Central Catheters (CICC, n = 4; 17.4%), and Femorally Inserted Central Catheters (FICC, n = 3; 13%). Short peripheral cannulas (SPC) were the most represented PVADs (n = 257; 86%), followed by long peripheral cannulas (LPC) (32; 10.7%), and midline (MC) (n = 10; 3.3%). CVADs were appropriate in 82.6% of cases, whereas PVADs' appropriateness fell to 43.1%. Overall, 47 VAD failures were observed: 6 (26.1%) CVADs and 41 (13.7%) PVADs. CONCLUSION: This study found a high prevalence of inappropriate VAD selection in hospitalised patients, especially among PVADs, although with no increased risk of complications. Further studies are needed to address effective strategies for improving the selection of VADs.
No takes yet. Share an insight, caveat, or question.
Pinelli et al. (2026) conducted an observational in Hospitalized patients requiring vascular access devices (n=161). Appropriate selection of vascular access devices (VADs) according to international guidelines vs. None (observational study) was evaluated on Appropriate selection of central and peripheral vascular access devices as per international guidelines. Appropriate selection was achieved in 82.6% of central VADs and 43.1% of peripheral VADs with no increased risk of complications despite high rates of inappropriate VAD selection.
Synapse has enriched 10 related papers. Consider them for comparative context: