This work demonstrates improved contact resistance in MEMS switches using post-release metallization, indicating optimization potential.
This work reports a post-release sputter-metallization process for microelectromechanical systems (MEMS) switches with silicon-to-silicon (Si-to-Si) contacts fabricated by deep reactive ion etching. Platinum (Pt) was selectively deposited on the contacting platforms through a perforated mask. Alternatively, aluminum (Al) was deposited over a thin chromium (Cr) adhesion layer. Electrical measurements showed that Pt enabled a contact resistance on the order of 406 Ω at a 1 mA test current, whereas the resistance of Al/Cr coatings decreased from 7.94 kΩ at 1 mA to 270 Ω at 25 mA, a change that was potentially linked to oxidation of the Al. These results demonstrated successful coating, with uniform top-surface and edge coverage as revealed by energy-dispersive X-ray spectroscopy imaging. Overall, the results indicate that post-release metallization has the potential to improve the operational repeatability of Si-to-Si contact MEMS switches in static and dynamic tests; the findings also point to process refinements to further optimize contact resistance.
No takes yet. Share an insight, caveat, or question.
Shuaibu et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: