Answers are grounded in this paper and cite their sources.
This study proposes a method to enhance the overload resistance of silicon-based MEMS devices in high-impact environments using Ti metal coatings. Compared to Al, Ni, and Cu, Ti forms Ti–O–Si covalent bonds with single-crystal silicon, integrating excellent interfacial bonding and plastic energy dissipation. A 1 μm-thick Ti coating was deposited by magnetron sputtering, with low-temperature plasma surface activation improving the coating-substrate interface. Mechanical tests show surface activation enhances adhesion by 31.43% without significantly changing the coating’s intrinsic elastic modulus and hardness. A silicon-based MEMS electrothermal actuator has been used as a test case, impact tests demonstrate the Ti-coated device’s maximum undamaged impact amplitude increased from 18000 g to 21600 g (20.00% improvement). This study confirms Ti coatings effectively enhance MEMS structural reliability under high overload via the synergistic effects of interface strengthening and plastic energy dissipation.
No takes yet. Share an insight, caveat, or question.
Yang et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: