Key result
Predelivery fetal echocardiography and AMH parameters effectively predict the need for urgent BAS in TGA.
Cohort (n=34)
No
Predelivery assessment using fetal echocardiography and CMR during acute maternal hyperoxygenation identifies fetuses with TGA at high risk for requiring urgent neonatal balloon atrial septostomy.
Enables targeted perinatal management in high-risk fetal TGA; extends noninvasive predictors of urgent neonatal BAS.
Objective Newborns with dextro‐transposition of the great arteries (TGA) without adequate intracardiac shunting of oxygenated blood are at imminent risk of severe hypoxia at birth. Using fetal echocardiography and cardiac magnetic resonance imaging (CMR) in room air (RA) and during acute maternal hyperoxygenation (AMH), we sought to identify predelivery imaging features predictive of neonatal hypoxia and the need for urgent balloon atrial septostomy (BAS) within the first 3 h after birth. Methods This was a prospective single‐center cohort study of pregnancies with TGA with an intact ventricular septum (IVS) or a single ventricular septal defect (VSD) ≤ 4 mm. Fetal echocardiography and, if feasible, CMR were conducted concurrently at 34–38 weeks' gestation. Cardiac structures, including the foramen ovale (FO) and atrial septum, were examined using two‐dimensional and Doppler echocardiography. CMR was used to quantify fetal weight, brain volume and vascular oxygen saturation (SaO 2 ). Both imaging modalities were used to assess fetal vascular blood flows in RA and during AMH. Postnatal data collected included preductal oxygen saturation (SpO 2 ) and the need for and timing of BAS. Univariable logistic regression analysis was used to evaluate associations between predelivery imaging features and the need for urgent neonatal BAS. Results Of 34 newborns with TGA/IVS ( n = 29) or TGA/VSD ( n = 5), 23 (68%) underwent neonatal BAS, including 12 cases of urgent BAS < 3 h after birth for persistent preductal SpO 2 < 70%. A fetal echocardiogram was obtained in all cases, while 26/34 (76%) underwent CMR, including 9/12 (75%) cases that underwent urgent BAS. On univariable logistic regression analysis, abnormal atrial septal flap morphology in RA ( P = 0.004), effective FO size ≤ 3.4 mm during AMH ( P = 0.0024) and constricted or continuously reversed diastolic flow across the ductus arteriosus (DA) during AMH ( P = 0.0006) were the most significant predictors of urgent neonatal BAS. On CMR, fetuses with an ascending aorta (AAo)/main pulmonary artery (MPA) SaO 2 ratio > 1 during AMH were significantly more likely to undergo urgent BAS postnatally (odds ratio, 28.6 (95% CI, 1.1–620.3); P = 0.0084). Conclusion In fetuses with TGA, predelivery assessment of atrial septal morphology in RA, as well as effective FO size, DA flow pattern and AAo/MPA SaO 2 ratio > 1 during AMH, are the most useful variables for predicting the need for urgent neonatal BAS.
No takes yet. Share an insight, caveat, or question.
Jaeggi et al. (2026) conducted a cohort in dextro-transposition of the great arteries (TGA) (n=34). Predelivery fetal echocardiography and CMR features was evaluated on Need for urgent neonatal balloon atrial septostomy (BAS) within the first 3 h after birth (OR 28.6, 95% CI 1.1-620.3, p=0.0084). Predelivery AAo/MPA SaO2 ratio > 1 during acute maternal hyperoxygenation on CMR significantly predicted the need for urgent neonatal balloon atrial septostomy (OR 28.6; 95% CI 1.1-620.3; P=0.0084).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: