Key result
PROMIS CAT-PF slightly outperforms DASI in predicting 30-day death or myocardial injury after elective surgery.
Why the study?
To compare PROMIS CAT-PF to DASI as a potential alternative physical function domain assessment to assist with preoperative risk assessment.
Does PROMIS CAT-PF perform as well as DASI in predicting 30-day postoperative death or myocardial injury in adults undergoing elective surgery?
Observational
Does PROMIS CAT-PF perform as well as DASI in predicting 30-day postoperative death or myocardial injury in adults undergoing elective surgery?
Absolute Event Rate: 0.773% vs 0.712%
PROMIS CAT-PF performs similarly to DASI for preoperative risk assessment, offering a small incremental benefit in predicting 30-day adverse postoperative outcomes and potentially reducing redundant questionnaire burden.
May reduce preoperative questionnaire burden via PROMIS CAT-PF versus DASI; extends evidence for modest incremental value in elective surgery risk assessment.
Objective: To compare the performance of the patient-reported outcomes measurement information system computer adaptive testing-physical function (PROMIS CAT-PF) to the Duke Activity Status Index (DASI) as a potential alternative physical function domain assessment to assist with preoperative risk assessment.Patients and Methods: Patients consisted of a retrospective convenience sample of all adults who had a DASI or PROMIS CAT-PF score obtained from January 1, 2021 to December 31, 2022, within 90 days prior to elective surgery.DASI and PROMIS CAT-PF obtained within one month before a stress test was used to assess the correlation between actual metabolic equivalents attained and the 2 patient-facing questionnaires.To assess the ability to predict adverse outcomes, we used a composite outcome of either death or myocardial injury within 30 days of the surgery.Results: In comparing DASI and PROMIS CAT-PF correlation to actual metabolic equivalents achieved on stress testing, the DASI Spearman's coefficient of 0.46 (95% CI, 0.32-0.58)was numerically better than the PROMIS CAT-PF Spearman's coefficient of 0.39 (95% CI, 0.21-0.52);however, the difference was not statistically significant.Using a composite outcome of either death or myocardial injury, DASI (area under the curve of 0.712) and PROMIS CAT-PF (area under the curve of 0.773) reported fair predictive utility.The 2 patient-reported physical function domain scores showed weak correlation (=0.509).Conclusion: PROMIS CAT-PF performs as well as DASI, demonstrating a small incremental benefit in predicting adverse postoperative outcomes, and could be an alternative physical function domain assessment used in the preoperative evaluation of patients.
No takes yet. Share an insight, caveat, or question.
Nyman et al. (2026) conducted an observational in Preoperative assessment for elective surgery. PROMIS CAT-PF vs. DASI was evaluated on Composite outcome of death or myocardial injury within 30 days of surgery (AUC). PROMIS CAT-PF demonstrated fair predictive utility for 30-day postoperative death or myocardial injury, performing slightly better than DASI (AUC 0.773 vs 0.712).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: